HC System


Fastening system

Chemical attachment system

Fastening type

Concealed fasteners

Thickness

6mm+

Outlet

Adjustable build-up

Certification

Sistema HC

The HC (HIDDEN CHEMICAL) system is an exclusively chemically-attached, ventilated facade system featuring hidden fixings to the subframing. It is specifically designed for exterior facade cladding using 6 mm thick Neolith panels.

For safety reasons, a fiberglass mesh is applied to the back of the panels to prevent shattering caused by accidental breakage.

This system includes dead-load and wind-load brackets, vertical profiles, and a chemical adhesion system for the Neolith cladding panels, primarily based on polyurethane sealant.

Both the profiles and Neolith panels must be pre-treated for enhanced adhesion and then installed with polyurethane structural sealant and double-sided tape to ensure the panels stay in place during the curing process of the structural adhesive.

Irregularities in the substrate can be corrected by the in-and-out tolerance between the T-profile and the brackets, creating a perfectly plumb facade.

A minimum horizontal and vertical joint of 5 mm between Neolith panels is recommended for proper installation.

Distribution of the substructure and installation

Spacing between brackets and vertical profiles depends on the facade cladding design (joint location), as well as the type of substrate, project wind loads, and structural assumptions.

Vertical profiles are installed onto the dead-load and windload brackets, following the facade joints.

A pull-out test may be required to determine the substrate’s load-bearing capacity before defining the bracket spacing.

How to apply chemical fixation

Chemical fixation consists on the direct application of adhesive and double-sided self-adhesive strip to the vertical profiles. For optimal adhesion, it is essential to pre-treat both the Neolith panels and the vertical profiles. The general steps to be carried out are described below:

01. Cleaning

Both the profiles (once fixed) and the panels must be free of dust or any other contaminants that could compromise the bond. For extremely dirty panels, clean using acetone or methyl ethyl ketone (avoid using turpentine).

After allowing the cleaning products to evaporate for 10 minutes, apply the activator to both the profile and the back of the panel, focusing on the area that will align with the profiles. Use disposable cellulose paper to apply the activator, rubbing from top to bottom and always in a single direction (avoid circular motions). Repeat the application as many times as needed until the paper no longer gets stained. Use a new piece of paper for each application.

Once the primer has dried (25 min. approx. depending on the manufacturer and atmospheric conditions) the double-sided adhesive strip should be applied vertically and continuously on the profiles. This strip is used for the initial fastening of the cladding panels until complete curing (or polymerization) of the adhesive and to ensure the correct dimensions of the adhesive bead.

The adhesive should only be applied vertically and continuously, forming a triangular bead using the special V-shaped nozzle. The adhesive should always be applied between +5°C (41°F) and +35°C (95°F) of ambient temperature. Typically, two lines of elastic adhesive are applied along the vertical “T” profile, while a single line is applied on the “L” profile. Depending on the manufacturer, the adhesive must be applied within a maximum of 2 hours after the primer has been applied.

The Neolith panel should be placed within 10 minutes of applying the adhesive, after removing the protective film from the double-sided strip. Once the panel is correctly positioned, it should be pressed firmly onto the profiles to ensure it makes contact with the strip. After the panel has made contact with the strip, no adjustments can be made.

Other installation systems

VM System

VM System

Sistema HC Slim

HC Slim System

Sitema HC-R

HC-R System

Sistema HR

HR System

Sistema HU

HU System

Sistema Strongfix